ISO 11135-1 PDF

Product Details BS EN ISO specifies requirements for the development, validation and routine control of an ethylene oxide sterilization process for medical devices. A sterile medical device is one that is free of viable microorganisms. International Standards that specify requirements for validation and routine control of sterilization processes, require, when it is necessary to supply a sterile medical device, that adventitious microbiological contamination of a medical device prior to sterilization be minimized. Such medical devices are non-sterile. The purpose of sterilization is to inactivate the microbiological contaminants and thereby transform the non-sterile medical devices into sterile ones.

Author:Zulugrel Voodooktilar
Country:El Salvador
Language:English (Spanish)
Genre:Love
Published (Last):11 June 2013
Pages:216
PDF File Size:7.69 Mb
ePub File Size:6.23 Mb
ISBN:121-6-20049-799-4
Downloads:76829
Price:Free* [*Free Regsitration Required]
Uploader:Dolrajas



Product Details BS EN ISO specifies requirements for the development, validation and routine control of an ethylene oxide sterilization process for medical devices. A sterile medical device is one that is free of viable microorganisms.

International Standards that specify requirements for validation and routine control of sterilization processes, require, when it is necessary to supply a sterile medical device, that adventitious microbiological contamination of a medical device prior to sterilization be minimized. Such medical devices are non-sterile. The purpose of sterilization is to inactivate the microbiological contaminants and thereby transform the non-sterile medical devices into sterile ones.

For a given treatment, the probability of survival is determined by the number and resistance of microorganisms and by the environment in which the organisms exist during treatment.

It follows that the sterility of any one medical device in a population subjected to sterilization processing cannot be guaranteed and the sterility of a processed population is defined in terms of the probability of there being a viable microorganism present on a medical device.

BS EN ISO describes requirements that, if met, will provide an ethylene oxide sterilization process intended to sterilize medical devices, which has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and reproducible so that it can be predicted, with reasonable confidence, that there is a low level of probability of there being a viable microorganism present on product after sterilization.

Specification of this probability is a matter for regulatory authorities and may vary from country to country. Generic requirements of the quality management systems for design and development, production, installation and servicing are given in ISO and particular requirements for quality management systems for medical device production are given in ISO The standards for quality management systems recognise that, for certain processes used in manufacturing or reprocessing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product.

Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of the sterilization process monitored routinely and the equipment maintained.

Exposure to a properly validated, accurately controlled sterilization process is not the only factor associated with the provision of reliable assurance that the product is sterile and, in this regard, suitable for its intended use.

Ethylene oxide. Requirements for development, validation and routine control of a sterilization process for medical devices Status.

HILFE DIE HERDMANNS KOMMEN KRIPPENSPIEL PDF

BS EN ISO 11135:2014+A1:2019

Full Description This International Standard specifies requirements for the development, validation and routine control of an ethylene oxide sterilization process for medical devices in both the industrial and health care facility settings, and it acknowledges the similarities and differences between the two applications. NOTE 1 Among the similarities are the common need for quality systems, staff training, and proper safety measures. The major differences relate to the unique physical and organizational conditions in health care facilities, and to the initial condition of reusable medical devices being presented for sterilization. NOTE 2 Health care facilities differ from medical device manufacturers in the physical design of processing areas, in the equipment used, and in the availability of personnel with adequate levels of training and experience. The primary function of the health care facility is to provide patient care; medical device reprocessing is just one of a myriad of activities that are performed to support that function. NOTE 3 In terms of the initial condition of medical devices, medical device manufacturers generally sterilize large numbers of similar medical devices that have been produced from virgin material.